The
Microcirculation
213
A
dynamic model was later developed by the same group that
included resistance and capacitance, as well as time-varying compliance
properties. The model also provided description
of
vasomotion, capillary
filtration and re-absorption processes. This is illustrated in Fig.
7.3.6.